Substation Automation System Solution
Substation Automation System Solution
Substation Automation System Solution

The DF1800 Substation Automation System can perform various functions such as protection, monitoring, communication and control, etc. based on the computer and network technology. It is a dispersed, hierarchical and distributed object-oriented system, in which the IEDs and computers are substituted for lots of devices with single function such as relays, meters, indicators, automation devices and panels. Local Area Network (LAN) is also substituted for plentiful cables. The protection relays in the system are relatively independent to improve the operation reliability substation and reduce the maintenance work.


DF1800 system can meet the requirement for substation automation put forward in CIGRE, that is, telecontrol function(telesignal, telemeter, telecontrol, etc.), automatic control function(Voltage and Reactive Power Control, Load-shedding, Static Reactive Power Compensator Control, etc.), metering function, protection relay function, function for protection relay(fault record, fault location, fault line selection), interface function(with microprocessor anti-maloperation, power supply, meters, GPS, etc.), system function(communication with station and local SCADA, etc.).


Adopt the dual-configuration: two communication interfaces are used as the hot standby each other. The operation mode of Dual-processor Dynamically Competing for Host is adopted, in which two processors can operate either as a host and a standby, or as two hosts. This Dual-network adopts the mechanism of message distributary and standby each other for communication for the best performance of the whole network to ensure the communication stability and data real time.


Adopt the two-level distributed network: it consists of a station level network and bay level network. The network meets the demands of IEC61850 communication about the network of the substation automation system.


Station-level communication network is Ethernet. Its communication rate is 100Mbps. The communication media can be optical fiber cable, twisted-pair cable or coaxial cable. CSMA/CD(Carrier Sense Multiple Access with Collision Detection) is adopted, and the communication protocol is TCP/IP.


Bay-level communication network has two communication modes: One is Ethernet, whose communication rate is 10Mbps, using optical fiber cable or shielded cable; The other is FDKBUS field bus, using optical fiber cable or shielded cable. If using optical fiber cable, the network can be a dual-loop and self-recovery network and it has advantage of increasing reliability and flexibility. The protocol is FNP protocol of electric power industry.

Typical SAS Architecture